  • Magnetic stirrer H04-1 10 intelligent stirrer temperature control, independent speed regulation, independent heating constant temperature

Magnetic stirrer H04-1 10 intelligent stirrer temperature control, independent speed regulation, independent heating constant temperature

Overview:1、 Introduction: H04-1 multi head constant temperature and speed measuring magnetic stirrer is widely used in Colleges and universities, environmental protection, scientific research, health and epidemic prevention, petrochemical, metallurgy, medical…

Consulting

1、 Introduction:

  H04-1 multi head constant temperature and speed measuring magnetic stirrer is widely used in Colleges and universities, environmental protection, scientific research, health and epidemic prevention, petrochemical, metallurgy, medical and other departments. This instrument has good performance, no noise, no vibration and remarkable mixing effect. It is an ideal and necessary tool for laboratory technicians

 

2、 Technical parameters:

1. Electric source: single phase AC, 50 Hz, 220 V ± 10 v

2. Working mode: 10 sets of independent constant temperature control and separate speed regulation mixing

3. Heating mode: digital display temperature control

4. Heating power: 300wx10

5. Motor type: brushless motor

6. Working disk size: 125mmx10

7. Maximum mixing capacity: 2000mlx10

8. Temperature control range: room temperature - ~ 100 ° C ± 0.5 ° C

9. Speed regulation mode: stepless speed regulation: 0-2400r / min

10. Mixing mode: 10 mixing heads are used to speed the mixing separately

11. Constant temperature mode: 10 heating plates separately control temperature and constant temperature

12. Magnetic stirrer is suitable for heating or heating at the same time.

13. With single head stirring, heating constant temperature, multi station, high power, etc.

14. Fully enclosed heating plate without open fire, avoiding oxidation of heating wire, fast temperature rise and durability.

15. The heating power is adjustable and the temperature can be controlled.

16. It can be used with temperature controller to set the required temperature value and self-control constant temperature.

17. Digital display temperature control magnetic stirrer.

18. The stirring capacity (ML) is about 0-2000ml

19. Brushless motor power: 25W.

20. Heating power: 300W.

21. The surface temperature range (℃) and the oil temperature can reach 150-180.

22. Temperature control accuracy (℃) ± 1.

23. Stirring speed: 0-2000rpm


 

3、 Usage:

  When using the instrument, first check whether the accessories are complete, and then install the fixture in order, and plug in the temperature control sensor for standby. (Note: please insert the sensor according to the number, and do not exchange with each other, so as to avoid affecting the temperature control accuracy. Remember to put the required experimental solution into the beaker or flask, and then put it into the stirrer, and put it in the center of the chromium plating plate, Put the sensor of stainless steel rod into the liquid of the container, plug in the power supply, turn on the power switch, the indicator light is on, turn on the working switch, the indicator light is on, turn on the mixing switch respectively, adjust the speed control knob respectively, and select the mixing speed you need from left to right (from low speed to high speed), The speed display does not need to be set. The speed and speed will be displayed under the digital display of stirring start, and it is not allowed to start directly at high speed, so as to prevent the agitator from being out of sync and causing jumping. To set the temperature, press the set key to enter the temperature setting mode to set or view the set value. Press the set key to see the number flashing. In the setting mode, press the up button to increase the setting value and the down button to decrease the setting value. If you keep pressing the button, it will increase or decrease to the value you need. After setting, press the set button again to exit the setting mode and return to the normal working measurement mode.

 

Note: the following parameters have been adjusted by the company's technical department before delivery. Internal parameters can not be adjusted without special needs, so as to avoid errors.

 

  Adjust parameter SC: press the set key for 3 seconds and enter the internal parameter setting adjustment interface. The interface shows that SC is the error calibration value, indicating the error between the measured value and the actual value of the temperature controller. The default value is 0.0. You can press the set key again to display the flashing number to enter the adjustment state (the following parameter setting method is the same), and press the up or down button to adjust the value. (-9.9~9.9)


E: After setting, press the set key to enter the next parameter adjustment. The interface shows that e represents the advance of breakpoint control (only effective when p value is set to 0). The default value is 0.5, and the adjustment method is the same as that of SC.


P: Then press the set key to enter the third parameter. The interface shows that P indicates the setting of P value, and the meaning of P value is roughly the starting control temperature = set value - (10 / P value). If it is set to 50 degrees, when p is 10, it means that 49 degrees begin to control; when p is 4, it means that adjustment begins at 47.5 degrees. If the temperature overshoot is too large, adjust the p value appropriately. If the temperature rises too slowly or the control temperature is not reached, adjust the p value appropriately. Note: when p value is 0, the breakpoint control mode is entered. That is, the system PID fails. When the temperature is lower than (set value - E value)  , it will start heating, otherwise it will stop heating.


c: Press set key to enter parameter C. the last parameter is reserved in the system temporarily. Please do not adjust it. The default value is 10.0.


Al: press the set key to enter the setting of parameter Al, which indicates the high temperature alarm value. That is, when the temperature > set temperature + Al, the instrument will alarm at high temperature. Ti: press the set key to enter the setting of parameter ti. Ti is the timer and the unit is minutes. 0 means that the timing mode is off; otherwise, when the Ti value of the instrument works for minutes, it will enter the stop state and stop the output of the load end. After all parameters are set, press set key to save parameters and return to normal working state. When not working, power supply should be cut off. In order to ensure safety, grounding wire should be used. The instrument should be kept clean and dry, and no solution should enter the machine to avoid damaging the machine parts

 

4、 Precautions:

a) Heating time should not be too long, intermittent use can prolong life

b) It can work continuously at medium speed and 8 hours at high speed

c) Please read the manual carefully for correct use

d) If it is not used for a long time, please wipe it and put it in a dry and ventilated place


}