0086-519-82305398
Overview:1、 Product introduction: The operation of double-layer magnetic stirring is simple and stable, which makes the liquid stirring more fully and thoroughly. With stepless speed regulation, the liquid can be stably stirred in a wide range of speed. It is…
Consulting1、 Product introduction:
The operation of double-layer magnetic stirring is simple and stable, which makes the liquid stirring more fully and thoroughly. With stepless speed regulation, the liquid can be stably stirred in a wide range of speed. It is especially suitable for samples with small volume and high mixing requirements. It is an essential tool for petrochemical, medical and health, environmental protection, biochemical experimental analysis, education and scientific research.
2、 Technical parameters:
JB-12double layer magnetic heating agitator
JBSeries magnetic heating agitator adopts strong magnetic steel and large capacity stirring motor. The whole machine is beautiful and easy to operate. It has bidirectional and timing stirring function. It is an essential tool for petroleum, chemical, medical and health, environmental protection, biochemical laboratory, analysis room, education and scientific research
JB-12Double layer magnetic stirrer
Type No. |
Operation mode
|
Temperature Contrd Range (℃) |
Heating Power (W) |
Speed AdjustingRange (rpm) |
Working Size (mm) |
Maximum stirring capacity |
JB-12 |
Mixing of upper and lower layers |
Heating without temperature control |
250w×12 |
0~2400 |
¢125mm×12 |
12×2000ml |
3、 Instrument use and maintenance:
1. When using the instrument of our company, please first check whether the accessories are complete. Put the beaker or other containers to be stirred in the middle of the mixing tray, add the solution, put the stirrer in the beaker solution, and then plug in the power plug of the instrument. If it is a digital temperature control instrument, please put the sensor into the beaker. Please connect the plug and motor between the parts Add appropriate water, connect the power supply, turn on the switch, and turn on the speed control switch according to your own requirements to adjust the mixing speed,
2. The speed regulation is gradually adjusted from low speed to high speed. It is not allowed to start directly at high speed, so as to prevent the agitator from being out of sync, causing jumping and running deviation. It is not allowed to add it when it is not stirring, and cut off the power supply when it is not working,
3. The instrument shell should be properly grounded to avoid accidents. Liquid is strictly prohibited to enter into the machine to prevent damage to the host machine. After use, the power supply should be cut off and placed in a ventilated and dry place.
4. In case of pulsating or non stirring during mixing, please cut off the power supply and check whether the bottom of the running beaker is flat and the position is positive. At the same time, check whether the current voltage is between 220 V and 10 V, otherwise the above situation will occur.
Welcome to the official website of Runhua Instruments. We are a professional manufacturer of laboratory instruments. Quality and reputation a…
The water bath constant temperature shaker is a biochemical instrument that combines a temperature controllable constant temperature water ba…
Series of biochemical incubators:Features of 150A biochemical incubator: the biochemical incubator has the function of cooling and heating tw…
High-precision stirring water bath produced by Runhua Instruments:1) The general water bath does not have the circulating stirring function. …
Maintenance and maintenance of electric mixer1. Correct use and attention to the maintenance of the instrument to keep it in good working con…
What work should be done in the use of digital display stainless steel electric heating plate? Digital display stainless steel electric h…