Qyc-2102a liquid crystal large screen display intelligent program control function of large capacity full temperature shaker

Overview:Brief introduction of qyc-2102a large capacity full temperature shaker Large capacity full temperature shaker is also known as refrigerated gas bath constant temperature oscillator, also known as constant temperature shaker. The temperature control of…

Consulting

Brief introduction of qyc-2102a large capacity full temperature shaker

  Large capacity full temperature shaker is also known as refrigerated gas bath constant temperature oscillator, also known as constant temperature shaker. The temperature control of this series of products adopts advanced system and LCD display. High precision temperature control, convenient temperature regulation, accurate and intuitive indication, superior and reliable performance. The refrigeration gas bath thermostatic oscillator, incubator, working room has lighting device for easy observation, high-quality fully closed compression mechanism is adopted, and high-quality circulating fan is equipped in the box to force air circulation and convection, so as to make the temperature more uniform


2、 Purpose:

  Large capacity full temperature shaker is widely used in environmental monitoring, teaching experiment, medical and health, epidemic prevention inspection, drug inspection, zoobotany, marine science, food engineering and other scientific research and production departments. It is a professional experimental equipment with constant temperature refrigeration oscillation for water analysis, b0d determination, bacterial cells, mold virus, microbial culture and preservation, plant cultivation, seed cultivation test.



Large capacity full temperature shaker (also known as constant temperature air shaker) is a kind of constant temperature oscillation equipment with controllable temperature

1. Accurate digital display of temperature control.

2. The oxygen supply circulation system is set up, and the constant temperature working chamber is supplied with sufficient oxygen.

3. It is equipped with timing and constant speed devices.

4. The stainless steel universal fixture can be used in the experiments of various containers, especially for the cultivation and preparation of biological samples for a variety of comparative tests.

5. Stepless speed regulation, stable operation, simple and safe operation.

6. The inner cavity is made of high quality stainless steel with good corrosion resistance.



3、 Technical parameters:

Instrument model

QYC-2102A

supply voltage

220V 50Hz

Motor power

950W

oscillation frequency

30-300r/min

Oscillation amplitude

30mm

Constant temperature range

5-60℃

control accuracy

± 0.1 ℃ (constant temperature) fluctuation ± 0.5 ℃

Timing range

0-9999 minutes or hours

Working dimensions

850*580*750mm

Size of rocker plate

750x480mm      Standard configuration:250mlx58

Dimensions about:940x760x1320mm
Number of shakers Two
Maximum capacity  
 100mlx90/250mlx58/500mlx50/1000mlx26

                                     

5、 Before using large capacity full temperature shaker

1. Please read this manual carefully before use.

2. The working plane of the machine should not be excessively smooth (e.g. tiles, etc.).

3. The electrical rated parameters of the socket provided by the user shall not be less than that of the machine.

4. It is forbidden to use the whole machine in direct sunlight.

5. The speed regulation should start slowly from low speed to high speed.

 

6、 Instructions for large capacity full temperature shaker:

1. Fill the test bottle and keep balance. If it is a dual function machine, set the oscillation mode.

2. Turn on the power supply and set the speed and time according to your own needs. If you need to work for a long time, set the digital display meter to be normally open, the speed is constant speed setting function, and the speed error is zero.

3. Turn on the power switch and set the constant temperature:

(1) Put the control digital display meter in the "setting" section, and the temperature displayed on the display screen is the set temperature. Adjust the up and down keys of the instrument to set the temperature you need. (the working temperature you set should be higher than the ambient temperature, and the machine will start to heat up. (if it is lower than the ambient temperature, otherwise the machine will not work.)

(2) Place the small switch of the control part at the "measurement" end. At this time, the temperature displayed on the display screen is the actual temperature of the air in the test chamber. With the change of the air temperature in the box, the number displayed will also change accordingly.

(3) When heating to the temperature you need, the heating will automatically stop and the green indicator light will be on; when the heat emission in the test chamber is lower than the temperature set by you, a new round of heating will start again.


7、 Turn on the oscillation device:
1. Turn on the oscillation switch on the control panel, and the indicator light will be on.

2. Adjust the oscillation speed knob to the desired oscillation frequency.

3. After work, cut off the power supply and set the speed control knob and temperature control knob to the lowest point. Clean the machine and keep it clean.


8、 Set temperature: refer to the detailed digital display operation instructions.

  Notes for large capacity full temperature shaker:

1. The appliance should be placed on a firm working table, and the environment should be clean and tidy with good ventilation.

2. The power socket provided by users should be well grounded.

3. It is strictly forbidden to move the machine during normal operation.

4. Do not hit the machine.

5. Children are not allowed to approach the machine to prevent accidents.

6. Make sure that the power supply has been cut off before replacing the fuse.

7. Please clean the machine after use, no water drop or dirt remains.


}
Video

    No video highlights...
Photo
No photo collection...
Customer
Flash Demo

Project
No related case...
Related articles
Related products
Consulting

Copyright 2020 Changzhou Runhua Electric Co., Ltd. Copyright Design by:EastNet [Manage]
Top