Overview:Introduction of RH-500B Intelligent Light incubator1. Product introduction:The new light box structure is manufactured by high quality cold plate whole moulding, the inner liner is made of high quality stainless steel mirror panel, hollow glass, the s…

Consulting

Introduction of RH-500B Intelligent Light incubator

1. Product introduction:

  The new light box structure is manufactured by high quality cold plate whole moulding, the inner liner is made of high quality stainless steel mirror panel, hollow glass, the separator is made of high quality and high density foaming material, the insulation effect is good, the weight is light, the overall shape is beautiful, and the control system is made of PC P.I.D.LCD control, large screen LCD, digital display, 6-level adjustable light source, accurate and intuitive, high accuracy, convenient and reliable temperature adjustment, easy to observe.The refrigeration system is a high quality fully enclosed compressor.Fast cooling and low noise, with 2 high-quality fan units inside the box, forced air convection, more even temperature distribution.Simulate sunshine exposure, gentle light, seed incubator use: suitable for cultivation and preservation of bacteria, molds, microorganisms, tissue cells, plant cultivation, breeding tests, mycology, mould engineering research; biological products, medicines, vaccine blood and various specimens preservation and testing, is genetic, medical, agricultural, forestry, environmental science, animal husbandry, aquaculture and other productionAnd ideal experimental equipment for scientific research departments.


2. Technical parameters:

1. Effective volume: 500L

2. Temperature control range: Lighting: 5-50 degrees no light: 0-60 degrees

3.Precision of temperature control: +0.5

4. Temperature fluctuation: +0.1

5. Heating power: 900W

6. Power supply voltage: 220V50HZ

7. Operating size: 650x700x1100mm

8.Match 3 pallets (304 stainless steel)

9. Refrigeration power: 400W [Refrigerant uses high quality R134a environmentally friendly and fluorine-free type]

10. Intelligent lighting 6 segments controllable

11. Light intensity can be set time and light intensity according to your needs. Check the detailed operation instructions of the instrument for details.

3. Instructions for use:

1. Connect the power supply, close the power switch, power on the whole machine, the power indicator inside the switch is on.

2. Refer to the instruction manual of the intelligent digital temperature controller for temperature control settings.Keep dry and ventilated, all switches on the front panel should be in non-working state.The test samples placed in the incubator should be kept at an appropriate distance.Favors the convective circulation of cold and hot air, plugs in the power supply, turns on the switch, lights up, and selects the culture temperature.

3. If you need lighting to turn on the lighting switch, set the temperature, press the SET key, and all the data blinks in the lower row, indicating that you have entered the set state, press the arrow down key, set the value to decrease, press the SET key again after you have reached the desired set temperature, it means that you have set the temperature for working state, and press the arrow up key to increase the set value.[See Instrument Operation Instructions for detailed operation instructions]

4. The incubator has a power-off protection function and a delay function of about one and a half minutes. It takes about two minutes for the compressor to start up again after shutdown.



4. Maintenance and maintenance of incubators:

1. The outer shell of the incubator should be reliably grounded

2. Keep the incubator in a cool, dry, well ventilated place away from heat sources and sunlight. Keep it stable to prevent vibration and noise.

3. In order to ensure effective heat dissipation of the condenser, the distance between the condenser and the wall should be greater than 10cm, the side of the box should be 5cm apart, and the top of the box should be 30cm apart.

4. The incubator should avoid collision, shaking and vibration during handling, maintenance and maintenance. The maximum tilt is less than 45 degrees.

5.If the instrument suddenly does not work, check if the fuse (behind the box) is burnt out and check the power supply.


}