0086-519-82305398
Overview:Gnp-9080 series water-proof constant temperature incubator Suitable for medical and health, medicine, biology, chemistry, agricultural science and other scientific research departments for constant temperature training necessary professional equipmen…
ConsultingGnp-9080 series water-proof constant temperature incubator
Suitable for medical and health, medicine, biology, chemistry, agricultural science and other scientific research departments for constant temperature training necessary professional equipment. The stainless steel working room is made by argon arc welding with anti bacteria stainless steel water jacket structure, which is durable. The microcomputer intelligent temperature control instrument can display the set temperature and the temperature in the box at the same time. It has the function of parameter memory and call recovery protected by power failure, crash state and data loss. It has over temperature, sensor fault, leakage, over-current, water level too low protection alarm function, timing function, low water level stop heating. The independent temperature limit alarm system can automatically interrupt when the temperature limit exceeds the limit, so as to ensure the safe operation of the experiment without accidents (optional). The outer door is equipped with observation window or double door structure, which is convenient for observation and does not affect the temperature inside the box. In addition to the above functions, the upgraded LCD intelligent temperature controller has more accurate temperature control, temperature fluctuation ± 0.3 ℃, and can be equipped with RS-485 interface. It can be connected with printer or computer, and can record the change of temperature parameters.
Technical parameters of GNP series water-proof constant temperature incubator:
Model Tech. parameters |
GNP-9050 |
GNP-9080 |
GNP-9160 |
GNP-9270 |
Volume |
50L |
80L |
160L |
270L |
Supply voltage |
~220V 50HZ |
|||
Heating mode |
Water-jacket type |
|||
Temp. range |
Room temp. +5~65℃ |
|||
Temp. resolution |
0.1℃ |
|||
Temp. fluctuation |
±0.5℃ |
|||
Temp. homogeneity |
±0.5℃ |
|||
Consumed power |
320W |
470W |
620W |
770W |
Size of workroom(mm) |
350×350×400 |
400×400×500 |
500×500×650 |
600×600×750 |
Outline size(mm) |
510×480×710 |
560×530×810 |
660×630×960 |
760×730×1060 |
Timing range |
1-999min |
|||
Shelves (normal) |
2 |
2 |
3 |
3 |
Remark |
E: LCD display |
Structure of water-proof constant temperature incubator:
A vertical box structure, inner tank made of stainless steel.
B. the temperature is displayed by digital, intuitive and clear, and the temperature error is less than 0.5 ℃
C. square type observation window is set on the door. Easy to view the samples in the studio.
D overflow device to prevent high water level.
E. good insulation and safe heating.
F strong thermal insulation performance
Characteristics of water-proof constant temperature incubator:
1. The water jacket of the incubator is made of stainless steel argon arc welding, which is durable.
2. Water jacket structure, accurate and reliable temperature control, without the disadvantage of over balance of temperature.
3. The temperature is controlled by digital display. If the set value is exceeded or the water level in the water clip is too high or too low, the sound and light alarm will be sent out automatically.
4. Silicone rubber sealing and toughened glass double door anti leakage device are adopted, which is convenient for observation and does not affect the temperature in the box.
Usage of water-proof constant temperature incubator:
Inject water from the water inlet (above the back plate) into the stainless steel tank, and the water level reaches 2cm below the overflow outlet. Then, turn on the power supply, put the articles to be cultivated into the studio, close the door of the studio, turn on the power switch, and set the required temperature (CNC device, error ≤ 0.5 ℃)
Precautions for water-proof constant temperature incubator:
a. It is strictly forbidden to dry burn and heat without water, so as to avoid burning out the heating pipe.
b. The instrument shell should be properly grounded to avoid accidents.
c. Do not turn the instrument upside down to avoid water overflow.
d. In order to reduce scale, distilled water is recommended. Note: Studio volume can be customized according to customer requirements
Welcome to the official website of Runhua Instruments. We are a professional manufacturer of laboratory instruments. Quality and reputation a…
The water bath constant temperature shaker is a biochemical instrument that combines a temperature controllable constant temperature water ba…
Series of biochemical incubators:Features of 150A biochemical incubator: the biochemical incubator has the function of cooling and heating tw…
High-precision stirring water bath produced by Runhua Instruments:1) The general water bath does not have the circulating stirring function. …
Maintenance and maintenance of electric mixer1. Correct use and attention to the maintenance of the instrument to keep it in good working con…
What work should be done in the use of digital display stainless steel electric heating plate? Digital display stainless steel electric h…