  • Digital biochemical incubator shp-250 intelligent LCD over temperature automatic alarm program settings, welcome to buy

Digital biochemical incubator shp-250 intelligent LCD over temperature automatic alarm program settings, welcome to buy

Overview:1、 Product introduction: The structure of biochemical incubator is made of high-quality cold plate, the inner tank is made of high-quality anti-corrosion materials, the glass door observation window is convenient for observation, the insulation mater…

Consulting

1、 Product introduction:

  The structure of biochemical incubator is made of high-quality cold plate, the inner tank is made of high-quality anti-corrosion materials, the glass door observation window is convenient for observation, the insulation material is polyurethane foam, with good heat preservation, light weight and beautiful overall appearance. The control system adopts microcomputer control and digital display, which is accurate and intuitive, high precision, convenient and reliable temperature adjustment, and convenient for observation. The refrigeration system is made of high quality hermetic compressor with three copper tubes. This machine has the advantages of fast cooling speed and low noise. Two high-quality fans are installed in the box to force air convection and make the temperature distribution more uniform. Application of biochemical incubator: it is suitable for the cultivation and preservation of bacteria, mold, microorganism, tissue cells, plant cultivation, breeding test, mycology, mold engineering research; preservation and test of biological products, drugs, vaccines, blood and various specimens. It is an ideal experimental equipment for production and scientific research departments of genetics, medicine, agriculture, forestry, environmental science, animal husbandry, aquatic products, etc.


2、 Technical parameters:

1. Effective volume: 250L
2. Temperature control range: 5-50 ℃
3. Temperature control accuracy: ± 0.5
4. Temperature fluctuation: ± 0.1
5. Heating power: 600W
6. Power supply voltage: 220 V 50 Hz 7. Working size: 600 x 550 x 750 mm
8. Each instrument is equipped with 4 pallets, and additional pallets will be charged [3 pallets as standard]
9. Overall dimension: 700x680x1400mm
9. Cooling power: 300W
10. Refrigerant: R134a environment-friendly fluorine-free refrigerant



3、 Instructions for use:

1. Turn on the power, close the power switch, the whole machine is powered on, and the power indicator in the switch is on

2. Please refer to the manual of intelligent digital temperature controller for temperature control setting. Keep dry and ventilated. All switches on the front panel should be in non working state. The experimental samples placed in the incubator should be kept at a proper distance. It is conducive to the convection circulation of cold and hot air. Turn on the power supply, turn on the switch, and the indicator light is on; select the culture temperature.


3. If lighting is needed, turn on the lighting switch and set the temperature. Press the set key, and the data in the lower row will flash, which means entering the setting state. Press the arrow down key and the set value will decrease. After pressing the set key to the required setting temperature, it means that the working state is entered. The temperature setting is completed and the setting value is increased. Pressing the arrow up key is the same.

4. The incubator has the function of power-off protection and a minute and a half delay function. It takes about one minute to restart the compressor after shutdown



4、 Maintenance of biochemical incubator:

1. The shell of incubator should be grounded reliably


2. The incubator should be placed in a cool, dry, well ventilated place away from heat sources and sunlight, and placed stably to prevent vibration and noise.

3. In order to ensure the effective heat dissipation of the condenser, the distance between the condenser and the wall should be greater than 10 cm, the side of the box should have a space of 5 cm, and the top of the box should have a space of 30 cm.

4. The incubator should avoid collision, shaking and vibration during handling, repair and maintenance, and the maximum gradient should be less than 45 degrees.

5. If the instrument doesn't work suddenly, please check whether the fuse (behind the box) is burnt out and check the power supply.



Changzhou Runhua Electric Appliance Co., Ltd

Address: No.26, Jinsheng East Road, Jintan City, Jiangsu Province

Tel: 0519-82305398 82301086 82306938


}