0086-519-82305398
Overview:Description of hy-4a digital display tachometer oscillator Multi purpose adjustable speed oscillator is widely used in laboratories of colleges and universities, environmental protection, scientific research, health, epidemic prevention, petroleum, ch…
ConsultingDescription of hy-4a digital display tachometer oscillator
Multi purpose adjustable speed oscillator is widely used in laboratories of colleges and universities, environmental protection, scientific research, health, epidemic prevention, petroleum, chemical industry and other units. It has the characteristics of generous appearance, large capacity, low noise, light weight, small size, adjustable speed and timing device. It is an ideal and necessary tool for laboratory staff.
Performance of multi-purpose adjustable speed oscillator:
1: Power supply: AC 220 V, 50 Hz
2: Motor power: 120W
3: Stepless speed regulation: 0-320 times / min
4: Oscillation amplitude: Reciprocating 20 mm
5: Timing: maximum 120 minutes
6: With speed digital display: 0-300 rpm
7: With a for digital display speed measurement, without a for common oscillation work products.
How to use the multi-purpose adjustable speed oscillator:
1: First, put the container (bottle) to be vibrated into the oscillation disk spring. The solution in the container should not exceed one third of the container, otherwise it must be plugged.
2: Check the timing knob and turn it to the on position or the time position you need to specify.
3: Turn the speed control knob to the minimum speed position against the clock, turn on the power switch, the power indicator light will be on, and then turn the speed control knob clockwise to the speed you need.
Notes for multi-purpose adjustable speed oscillator:
1: The multi-purpose adjustable speed oscillator adopts three hole safety socket, and the ground wire must be properly connected when using.
2: When working, the machine should be placed on a flat and solid table to prevent vibration.
3: The clamp spring is only used for fixing small and medium capacity bottles. Several springs should be removed or other methods should be adopted to reinforce the extra large container.
4: After the machine is used, turn off the power supply, put it in a dry and ventilated place, and keep it clean.
2、 Technical indicators of related series products:
Model index |
HY-1 |
HY-2 |
HY-3 |
HY-4/KS |
Speed range |
start—300rpm/min |
start—360rpm/min |
start—300rpm/min |
start— 300rpm/min |
Amplitude |
20mm |
20mm |
20mm |
20mm |
Timing range |
0—120min(Normally open) |
0—120min(Normally open) |
0—120min(Normally open) |
0—120min(Normally open) |
Dimensions |
510×480×300 |
520×300×240 |
750×500×330 |
440×300×240 |
Description of hy-4a digital display tachometer oscillator
Multi purpose adjustable speed oscillator is widely used in laboratories of colleges and universities, environmental protection, scientific research, health, epidemic prevention, petroleum, chemical industry and other units. It has the characteristics of generous appearance, large capacity, low noise, light weight, small size, adjustable speed and timing device. It is an ideal and necessary tool for laboratory staff.
Performance of multi-purpose adjustable speed oscillator:
1: Power supply: AC 220 V, 50 Hz
2: Motor power: 120W
3: Stepless speed regulation: 0-320 times / min
4: Oscillation amplitude: Reciprocating 20 mm
5: Timing: maximum 120 minutes
6: With speed digital display: 0-300 rpm
7: With a for digital display speed measurement, without a for common oscillation work products
How to use the multi-purpose adjustable speed oscillator:
1: First, put the container (bottle) to be vibrated into the oscillation disk spring. The solution in the container should not exceed one third of the container, otherwise it must be plugged.
2: Check the timing knob and turn it to the on position or the time position you need to specify.
3: Turn the speed control knob to the minimum speed position against the clock, turn on the power switch, the power indicator light will be on, and then turn the speed control knob clockwise to the speed you need.
Notes for multi-purpose adjustable speed oscillator:
1: The multi-purpose adjustable speed oscillator adopts three hole safety socket, and the ground wire must be properly connected when using.
2: When working, the machine should be placed on a flat and solid table to prevent vibration.
3: The clamp spring is only used for fixing small and medium capacity bottles. Several springs should be removed or other methods should be adopted to reinforce the extra large container.
4: After the machine is used, turn off the power supply, put it in a dry and ventilated place, and keep it clean.
2、 Technical indicators of related series products:
Model index |
HY-1 |
HY-2 |
HY-3 |
HY-4/KS |
Speed range |
start—300rpm/min |
start—360rpm/min |
start—300rpm/min |
start— 300rpm/min |
Amplitude |
20mm |
20mm |
20mm |
20mm |
Timing range |
0—120min(Normally open) |
0—120min(Normally open) |
0—120min(Normally open) |
0—120min(Normally open) |
Dimensions |
510×480×300 |
520×300×240 |
750×500×330 |
440×300×240 |
Welcome to the official website of Runhua Instruments. We are a professional manufacturer of laboratory instruments. Quality and reputation a…
The water bath constant temperature shaker is a biochemical instrument that combines a temperature controllable constant temperature water ba…
Series of biochemical incubators:Features of 150A biochemical incubator: the biochemical incubator has the function of cooling and heating tw…
High-precision stirring water bath produced by Runhua Instruments:1) The general water bath does not have the circulating stirring function. …
Maintenance and maintenance of electric mixer1. Correct use and attention to the maintenance of the instrument to keep it in good working con…
What work should be done in the use of digital display stainless steel electric heating plate? Digital display stainless steel electric h…