Overview:Brief introduction of Runhua qyc-200 refrigeration full temperature gas bath oscillator Refrigerated gas bath thermostatic oscillator is also known as constant temperature shaker. The temperature control of this series of products adopts advanced syst…
ConsultingBrief introduction of Runhua qyc-200 refrigeration full temperature gas bath oscillator
Refrigerated gas bath thermostatic oscillator is also known as constant temperature shaker. The temperature control of this series of products adopts advanced system and LED display. High precision temperature control, convenient temperature regulation, accurate and intuitive indication, superior and reliable performance. The incubator is also known as full temperature oscillator. It adopts high-quality fully enclosed compression mechanism with large cooling capacity. The box is equipped with fans and devices to force air convection and make the temperature distribution more uniform.
Purpose: Refrigerated gas bath thermostatic oscillator
Freezing gas bath thermostatic oscillator is suitable for environmental protection, medical teaching, health and epidemic prevention, drug inspection, animal and botany, marine science, food engineering and other scientific research and production departments. It is a special constant temperature equipment with oscillator for BOD determination of water analysis, cultivation and preservation of bacteria, viruses, molds and microorganisms, plant cultivation and breeding test.
Main technical parameters of refrigerated gas bath thermostatic oscillator product features:
The refrigerated gas bath thermostatic oscillator (also known as air thermostatic shaker) is a biochemical instrument which combines temperature controlled incubator and oscillator.
Its main characteristics are as follows
A: Temperature control precise digital display.
B: There are oxygen supply hole, water outlet hole and constant temperature working chamber.
C: With digital display timing speed regulation.
D: The universal spring bottle rack is especially suitable for the cultivation and preparation of biological samples for various comparative tests.
E: Stepless speed regulation, stable operation, simple and safe operation.
F: The inner cavity is made of stainless steel and has good corrosion resistance.
The main technical performance of the refrigerator gas bath thermostatic oscillator is as follows
Model of the instrument: qyc-200 cryostat oscillator
1、 Power supply: 220 V, 50 Hz, machine power: 1 900 w
2、 Heating power: 400W cooling power: 300W
3、 Timing range: 0 ~ 99 hours (or normally open)
4、 Oscillation frequency: starting - 300 rpm, adjustable
5、 Oscillation amplitude: 20 mm
6、 Constant temperature range: 0-50 ℃
7、 Oscillation method: reciprocating and gyratory (to be selected when purchasing)
8: Temperature control accuracy: 0.5 ℃
9: Special tips: add "a" after the model for temperature and speed dual digital display
Notice before using refrigerated gas bath thermostatic oscillator:
1. Please read this manual carefully before use.
2. The working plane of the machine should not be excessively smooth (e.g. tiles, etc.).
3. The electrical rated parameters of the socket provided by the user shall not be less than that of the machine, and good grounding measures shall be taken.
4. It is forbidden to use the whole machine in direct sunlight.
5. The speed regulation should start slowly from low speed to high speed.
Operating instructions for refrigerated gas bath thermostatic oscillator:
1. Fill the test bottle and keep balance. If it is a dual function machine, set the oscillation mode. (see the final figure for detailed settings)
2. Turn on the power supply and set the timing time according to the machine surface scale. If it needs to work for a long time, set the timer to the "normally open" position.
3. Turn on the power switch and set the constant temperature:
(1) Put the small control switch in the "setting" section, and the temperature displayed on the display is the set temperature. Adjust the up and down keys of the instrument to set the temperature you need. (the working temperature you set should be higher than the ambient temperature, and the machine will start to heat up. (if it is lower than the ambient temperature, otherwise the machine will not work.)
(2) Place the small switch of the control part at the "measurement" end. At this time, the temperature displayed on the display screen is the actual temperature of the air in the test chamber. With the change of the air temperature in the box, the number displayed will also change accordingly.
(3) When heating to the temperature you need, the heating will automatically stop and the green indicator light will be on; when the heat emission in the test chamber is lower than the temperature set by you, a new round of heating will start again.
4. Turn on the oscillation device:
(1) Turn on the oscillation switch on the control panel, and the indicator light will be on.
(2) Adjust the oscillation speed knob to the desired oscillation frequency.
5. After work, cut off the power supply and set the speed control knob and temperature control knob to the lowest point.
6. Clean the machine and keep it clean.
Precautions for refrigerated gas bath thermostatic oscillator:
1. The appliance should be placed on a firm working table, and the environment should be clean and tidy with good ventilation.
2. The power socket provided by users should be well grounded.
3. It is strictly forbidden to move the machine during normal operation.
4. Do not hit the machine.
5. Children are not allowed to approach the machine to prevent accidents.
6. Make sure that the power supply has been cut off before replacing the fuse.
7. Please clean the machine after use, no water drop or dirt remains.
Welcome to the official website of Runhua Instruments. We are a professional manufacturer of laboratory instruments. Quality and reputation a…
The water bath constant temperature shaker is a biochemical instrument that combines a temperature controllable constant temperature water ba…
Series of biochemical incubators:Features of 150A biochemical incubator: the biochemical incubator has the function of cooling and heating tw…
High-precision stirring water bath produced by Runhua Instruments:1) The general water bath does not have the circulating stirring function. …
Maintenance and maintenance of electric mixer1. Correct use and attention to the maintenance of the instrument to keep it in good working con…
What work should be done in the use of digital display stainless steel electric heating plate? Digital display stainless steel electric h…