  • HH series constant temperature water bath

HH series constant temperature water bath

Overview:HH series constant temperature water bath1、 The company uses 304 ා high quality stainless steel for one-time stretch forming. Replace the original product welding process. Ensure that the product in the long-term use of water leakage phenomenon. The…

Consulting

HH series constant temperature water bath

1、 The company uses 304 ා high quality stainless steel for one-time stretch forming. Replace the original product welding process. Ensure that the product in the long-term use of water leakage phenomenon. The four corners and bottom of the product are arc-shaped design, which makes it difficult to produce dead angle in the heating process and affect the uniformity of water temperature. The outer shell of the instrument is also formed by once drawing and extrusion. The shell is made of cold-rolled sheet, and the four corners are designed with outer arc. It is not only beautiful and elegant, but also improves the anti falling and compressive capacity of the instrument in the process of use and transportation, and is easy to clean. It can be widely used in chemical, medical, biological experiments and other industries.


2、 Technical parameters of series water bath boiler: (hh-1a / hh-2a / hh-4a / hh-6a)

model

  name

 Power Supply

temperature range

control accuracy

Dimensions

Tank size

heating
power


Number of working holes

HH-1A

Constant temperature water bath

220V50Hz

room temperature+5℃-99.9℃

±0.5℃

200x200x140mm

160x160x140mm

300W

1

HH-2A

Constant temperature water bath

220V 50Hzroom temperature

+5℃—99.9℃

±0.5℃

345x200x230mm

305x160x140mm

600W

2

HH-4A

Constant temperature water bath

 

 

 

345x345x230mm

305x305x140mm

800W

4

HH-6A

Constant temperature water bath

 

 

 

345x510x230mm

305x470x140mm

1200W

6


3、 Usage:

a) When using, water must be added into the pot first, and then the power supply is connected. Set temperature: press set key to set or view the temperature set point. Press set key once, and the nixie tube character starts to flash, indicating that the instrument enters the setting state. Press the Δ key to increase the setting value, press the ▽ key to decrease the setting value. Long press the Δ key or ▽ key, and the data will change rapidly. Once again, the set key will return to the normal working state, and the temperature setting is completed.

b) Advance setting: press set key for 3 seconds, and the instrument will enter the inner parameter setting state. The first parameter that appears and flashes is eoo, that is, the advance amount of heating stop. The advance parameter should be carefully adjusted. In order to reduce the temperature overshoot, the heating will be stopped in advance when the instrument controls the heating output. When the temperature drops below the advance value, the heating will start again. The output (relay) will not act within the range of the set value and advance amount, so as to reduce the relay action times and delay Long relay life. Example: if the set value is 50 ℃, the advance is 0. 5. Instrument control heating to 49. At 5 ℃, the relay releases and the temperature drops to 50. 0℃-0。 At 5 ℃, the relay is closed again. The larger the advance, the less the relay action times. If the advance is too large, the accuracy will be reduced. After adjusting the advance parameter, press set key for 3 seconds, and the instrument will return to normal working state.

c) Error correction: when confirming that the value displayed by the instrument is not the correct measurement value, the displayed value can be corrected. Press set key for 3 seconds to enter the inner menu of the instrument,. The first parameter that appears and flashes is eoo, that is, the advance value. Press the set key again to appear and flash, that is, the error correction parameter. This parameter can be modified with Δ or ▽ keys. The range of error correction is from - 9.9 ℃ to + 9.9 ℃, and then press the set key to exit. The correction value is 0 when the instrument is delivered from the factory. 0. When using, it is necessary to prevent the instrument with correct display from being corrected to incorrect.

Do not add too much water in the pot, so as to avoid water overflowing out of the boiler when boiling. Pay attention to that the water in the pot can not make the electric heating pipe out of the water surface, so as to avoid burning the electric heating pipe and causing water leakage.



4、 Precautions

(1) In order to ensure safety, please connect the ground wire when using.
(2) Do not add water and dry burn.
(3) When not working, the power should be cut off to prevent accidents.


  

Changzhou Runhua Electric Appliance Co., Ltd
Address: No.26, Jinsheng East Road, Jintan City, Jiangsu Province
website: www.runhuayiqi.com
Email: 394514722@qq.com
Tel: 0519-82305398
Fax: 0519-82306938


}
Video

    No video highlights...
Photo
No photo collection...
Customer
Flash Demo

Project
No related case...
Related articles
Related products
Consulting

Copyright 2020 Changzhou Runhua Electric Co., Ltd. Copyright Design by:EastNet [Manage]
Top