0086-519-82305398
Overview:1、 Brief introduction of the instrument: Hj-6 multi head magnetic stirrer is widely used in Colleges and universities, environmental protection, scientific research, health and epidemic prevention, petrochemical, metallurgy, medical and other departm…
ConsultingHj-6 multi head magnetic stirrer is widely used in Colleges and universities, environmental protection, scientific research, health and epidemic prevention, petrochemical, metallurgy, medical and other departments. This instrument has good performance, no noise, no vibration, and remarkable mixing effect. It is an ideal and necessary tool for laboratory technicians
2、 Technical parameters:
1. Electric source: single phase AC, 50 Hz, 220 V ± 10 v
2. Motor power: 25W × 6
3. Stepless speed regulation: 0 ~ 2400 rpm
4. Working size: tray diameter: 125mmx4
5. Heating alone: [temperature not controllable] please turn off the heating switch when heating is not needed!!!
6. Heating tray: stainless steel tray
7. Mixing capacity: 1000mlx6
8. Heating power: 250wx6
9. Mixing is controlled by separate power supply
3、 Usage:
When using the instrument, first check whether the accessories are complete, and then install the fixture in order, put the required solution into the beaker or flask, and then put the stirrer in the center of the chromium plating plate. Plug in the power supply, turn on the power switch, and the indicator light is on to indicate that the power source is connected, Turn on the working switch and the indicator light is on. Adjust the speed control knob from left to right (from low speed to high speed) to select the mixing speed you need. It is not allowed to start at high speed directly, so as to prevent the agitator from being out of sync and causing jumping. Do not heat separately when not working. Turn on the heating red switch when mixing. Cut off the power supply after use. To ensure safety, please connect the ground wire. Keep the instrument clean and dry. Do not allow solution to enter the machine to avoid damaging the machine
4、 Precautions:
Mixing time should not be too long, intermittent use can prolong life
Medium speed operation can work continuously. Medium speed operation is recommended
Please read the manual carefully for correct use
If it is not used for a long time, please wipe it and put it in a dry and ventilated place
Changzhou Runhua Electric Appliance Co., Ltd
Address: 26 Jinsheng East Road, Jintan City
website: www.runhuayiqi.com
Email: 394514722@qq.com
Tel: 0519-82305398 82301086
Fax: 0519-82306938
Welcome to the official website of Runhua Instruments. We are a professional manufacturer of laboratory instruments. Quality and reputation a…
The water bath constant temperature shaker is a biochemical instrument that combines a temperature controllable constant temperature water ba…
Series of biochemical incubators:Features of 150A biochemical incubator: the biochemical incubator has the function of cooling and heating tw…
High-precision stirring water bath produced by Runhua Instruments:1) The general water bath does not have the circulating stirring function. …
Maintenance and maintenance of electric mixer1. Correct use and attention to the maintenance of the instrument to keep it in good working con…
What work should be done in the use of digital display stainless steel electric heating plate? Digital display stainless steel electric h…