Welcome to visit Changzhou Runhua Electric Co., Ltd. Official website!
TEL

0086-519-82305398

Current location:Home > Products > Oscillator series > Gas bath thermostatic oscillator
PRODUCTS
  • Zd-85a gas bath thermostatic oscillator

Zd-85a gas bath thermostatic oscillator

Overview:D-85a multifunctional gas bath thermostatic oscillatorThe air bath constant temperature oscillator (air shaker) is a biochemical instrument which combines the incubator and the oscillator with controllable temperature. The intelligent integrated circu…

Consulting

D-85a multifunctional gas bath thermostatic oscillator

  The air bath constant temperature oscillator (air shaker) is a biochemical instrument which combines the incubator and the oscillator with controllable temperature. The intelligent integrated circuit is adopted for temperature control, and the setting is free of drift and LED display. The indication value is intuitive and accurate. This series of products are widely used in environmental protection, medical, health and epidemic prevention, animal and plant, food engineering and other laboratories.


ZD-85(A)、SHZ-82(A)、CHA-S(A) Vapour-bathing Constant Temperature Vibrator

TypeNo.

Temperature Contrd 

Range (℃)

Vibration Range (mm)

Vibration Frequence (rpm)

Time Fixed Range

The Whole Machine Power (W)

Working Size (cm)

Outside Size (cm)

ZD-85(A) Room temperature ~ 50 20 0~300 0~120 690 45×36 71×55×52
SHZ-82(A) Room temperature ~ 50 20 0~300 0~120 690 45×36 71×55×52
CHA-S(A) Room temperature ~ 50 20 0~300 0~120 580 44×36 71×47×52


1、 Brief introduction of zd-85a (digital display) gas bath thermostatic oscillator
  Air bath thermostatic oscillator (also known as air thermostatic shaker) is a kind of thermostatic gas box and oscillator with controllable temperature

  The combined biochemical instrument is an indispensable laboratory equipment for precise cultivation and preparation in scientific research, education and production departments such as plant, biology, microorganism, genetics, virus, environmental protection and medicine.


Its main characteristics are as follows

(1) Accurate temperature control and digital display;
(2) Oxygen supply holes are set up;
(3) With mechanical timing;
(4) The universal spring bottle rack is especially suitable for the cultivation and preparation of biological samples for various comparative tests;
(5) Stepless speed regulation, stable operation, simple and safe operation.



2、 Technical specifications of zd-85 (digital display) gas bath thermostatic oscillator
1. Please read this manual carefully before use.

2. The working plane of the machine should not be excessively smooth (e.g. tiles, etc.).

3. The electrical rated parameters of the socket provided by the user shall not be less than that of the machine, and good grounding measures shall be taken.

4. It is forbidden to use the whole machine in direct sunlight.

5. The speed regulation should start slowly from low speed to high speed.

6. The machine may shift when it vibrates at high speed, so it should be watched by someone.


3、 Zd-85 (digital display) gas bath thermostatic oscillator
1. Fill the test bottle and keep balance. If it is a dual function machine, set the oscillation mode. (see the final figure for detailed settings)

2. Turn on the power supply and set the timing time according to the machine surface scale. If it needs to work for a long time, set the timer to the "normally open" position.

3. Turn on the power switch and set the constant temperature:

(1) Set the small control switch to the "setting" section, and the temperature displayed on the display is the set temperature. Adjust the knob to set the temperature you need. (the working temperature set by you should be higher than the ambient temperature. At this time, the machine starts to heat up and the yellow indicator light is on, otherwise the machine will not work.)

(2) Place the small switch of the control part at the "measurement" end. At this time, the temperature displayed on the display screen is the actual temperature of the air in the test chamber. With the change of the air temperature in the box, the number displayed will also change accordingly.

(3) When heating to the temperature you need, the heating will automatically stop and the green indicator light will be on; when the heat emission in the test chamber is lower than the temperature set by you, a new round of heating will start again.

4. Turn on the oscillation device:

(1) Turn on the oscillation switch on the control panel, and the indicator light will be on.

(2) Adjust the oscillation speed knob to the desired oscillation frequency.

5. After work, cut off the power supply and set the speed control knob and temperature control knob to the lowest point.

6. Clean the machine and keep it clean.

4、 Precautions for zd-85 (digital display) gas bath thermostatic oscillator
1. The appliance should be placed on a firm working table, and the environment should be clean and tidy with good ventilation.

2. The power socket provided by users should be well grounded.

3. It is strictly forbidden to move the machine during normal operation.

4. Do not hit the machine.

5. Children are not allowed to approach the machine to prevent accidents.

6. Make sure that the power supply has been cut off before replacing the fuse.

7. Please clean the machine after use, no water drop or dirt remains.

}
Video

    No video highlights...
Photo
No photo collection...
Customer
Flash Demo

Project
No related case...
Related articles
Related products
Consulting

Copyright 2020 Changzhou Runhua Electric Co., Ltd. Copyright Design by:EastNet [Manage]
Top