Overview:HH-601B circulating low temperature water tank intelligent temperature controlHH-601B Low Temperature Tank InstructionsRefrigeration cycle tank, also known as low temperature constant temperature bath, is a high-precision constant temperature source w…

Consulting
HH-601B circulating low temperature water tank intelligent temperature control
HH-601B Low Temperature Tank Instructions
Refrigeration cycle tank, also known as low temperature constant temperature bath, is a high-precision constant temperature source with its own cooling and heating, and it has the function of a small chiller. It is widely used in research departments of petroleum, chemical industry, metallurgy, medicine, biochemistry, physical properties, testing and chemical analysis, colleges and universities, factory laboratories and metrology and quality inspection departments. Depending on the size of the tank opening, the constant temperature experiment can be carried out in the bath, or it can be connected to other equipment through a hose and used with a constant temperature source. Internal circulation: Through the pump to circulate the liquid medium in the tank, increase the uniformity of the temperature in the tank and reduce temperature fluctuations. External circulation: Through the circulation capacity of the pump, the water outlet is used to connect the heat preservation hose with the external equipment to form a closed loop, and flow back to the equipment water inlet to draw the constant temperature medium in the tank outside to establish an external constant temperature field. Application fields of circulating water constant temperature:

Digital display temperature control low temperature circulating water tank

Low temperature tank   structure:

The structure of the low-temperature constant-temperature pot is a metal rectangle, the outer shell is carefully made of cold-rolled steel plate, the stainless steel inner tank, the digital display temperature controller, the power supply, and the water pump are all installed in the control box.

HH-601B series digital display temperature control circulating low temperature tank Technical parameters:

model

name

The main technical parameters

HH-601B-5-5

Cryogenic tank

temperature range-5~100℃,≤±0.5℃,180*140*200mm,Pump flow8L/min

HH-601B-5-10

Cryogenic tank

temperature range-5~100℃,≤±0.5℃,250*200*200mm,Pump flow8L/min

HH-601B-5-15

Cryogenic tank

temperature range-5~100℃,≤±0.5℃,300*250*200mm,Pump flow8L/min

HH-601B-5-20

Cryogenic tank

temperature range-5~100℃,≤±0.5℃,300*250*260mm,Pump flow8L/min

HH-601B-10-5

Cryogenic tank

temperature range-5~100℃,≤±0.5℃,180*140*200mm,Pump flow8L/min

HH-601B-10-10

Cryogenic tank

temperature range-10~100℃,≤±0.5℃,250*200*200mm,Pump flow8L/min

HH-601B-20-15

Cryogenic tank

temperature range20~100℃,≤±0.5℃,300*250*200mm,Pump flow8L/min

HH-601B-20-20

Cryogenic tank

temperature range20~100℃,≤±0.5℃,300*250*260mm,Pump flow8L/min

HH-601B-20-5

Cryogenic tank

temperature range-20~100℃,≤±0.5℃,180*140*200mm,Pump flow8L/min

HH-601B-20-10

Cryogenic tank

temperature range-20~100℃,≤±0.5℃,250*200*200mm,Pump flow8L/min

HH-601B-20-15

Cryogenic tank

temperature range-20~100℃,≤±0.5℃,300*250*200mm,Pump flow8L/min

HH-601B-20-20

Cryogenic tank

temperature range-20~100℃,≤±0.5℃,300*250*260mm,Pump flow8L/min

HH-601B-30-5

Cryogenic tank

temperature range-30~100℃,≤±0.5℃,180*140*200mm,Pump flow8L/min

HH-601B-30-10

Cryogenic tank

temperature range-30~100℃,≤±0.5℃,250*200*200mm,Pump flow8L/min

HH-601B-30-15

Cryogenic tank

temperature range-30~100℃,≤±0.5℃,300*250*200mm,Pump flow8L/min

HH-601B-30-20

Cryogenic tank

temperature range-30~100℃,≤±0.5℃,300*250*260mm,Pump flow8L/min

Low temperature tank  set temperature:

Press the SET key to set or view the temperature set point. Press the SET key once and the digital tube characters start to flash, indicating that the instrument enters the setting state, press the △ key to increase the setting value, press the ▽ key to decrease the setting value, long press the △ key or ▽ key, the data will change quickly, press again SET key The instrument returns to the normal working state. After the temperature is set, the heating and circulating pump switches can be turned on. (If the temperature controller is an intelligent type, the temperature controller manual is attached separately).

Low temperature tank  application range:

The low-temperature thermostat is suitable for direct heating and cooling of precise constant temperature and auxiliary heating and cooling in biology, chemistry, physics, plants, chemical engineering and other sciences.

Low temperature tank   use method:

Before use, please read the instructions carefully, familiarize yourself with the instrument and control panel, use a megohmmeter to measure the power supply, plug, and ground for poor insulation or short circuit. Set the experimental temperature according to the temperature setting method, and start the experiment after the temperature is constant. Distilled water is best used for this thermostatic heating solution, and river water and hard water are forbidden. If tap water is used, the thermostatic pot should be cleaned once after each use to prevent the accumulation of scale on the heater from affecting the temperature. Sensitivity.



}