Overview:Operation manual of td4a-ws desktop electric centrifuge Td4a-ws table type electric centrifuge is a conventional laboratory centrifuge. It adopts high-quality brushless motor and digital display touch screen design. It can choose its own speed at will…

Consulting

Operation manual of td4a-ws desktop electric centrifuge

  Td4a-ws table type electric centrifuge is a conventional laboratory centrifuge. It adopts high-quality brushless motor and digital display touch screen design. It can choose its own speed at will with zero error. It is widely used in biology, medicine, chemistry and other scientific research, education and production departments. The highest speed of low-speed low-speed centrifuge is 4000R / min. it is used for radioimmunoassay identification and separation of cells and large particles. It has a stainless steel liner, which is safer and less noisy.


1、 Td4a-ws technical index of desktop electric centrifuge:

model

Maximum speed (speed regulation)

 Capacity

  Centrifugal force

 Timing range

 Working power supply

TD4A-WS

4000r/min

Standard configuration:15mlx24

10mlx24

 

   

 

      3235xg

 

 

0-99分钟

 

 

220V50HZ


Adaptive rotor:15mlx6/15mlx8/20mlx12/20mlx6


2、 Safety notice for td4a-ws desktop centrifuge: please read all instructions before using desktop centrifuge.

1. Before operation, the hollow pipe should be evenly put into the machine, and the machine should be started to run at high speed for 1-2 minutes, and the machine can work only after no abnormality is found.

2. Do not touch the rotating head in operation.

3. It is forbidden to turn the head in the state of unbalanced loading.

4. If the wire or plug is damaged or the electrical equipment fails, it should be repaired by professionals. The use of electrical equipment not recommended by the manufacturer will cause certain quality problems.

5. Do not use in direct sunlight.

6. Do not put the machine near the high temperature heater.

7. The rated parameters of the power socket provided by the user shall be greater than that of the machine, and good grounding measures shall be taken.

8. Never move the machine while it is running.

9. Strong impact is strictly prohibited.

10. When replacing the fuse, the socket should be pulled out from the power supply.

11. When running, the centrifuge cover must be tightly covered to prevent objects from entering and damaging the machine.

12. Keep children away from the machine in use.

13. It is strictly prohibited to use metal scrubbing material for scrubbing, and soft cloth should be dipped in alkali for scrubbing.



3、 Td4a-ws desktop electric centrifuge instructions

1. The table of td4a-ws electric centrifuge should be flat and solid, and the workshop should be clean, dry and well ventilated. Before starting up, wipe the inner cavity and the rotating head, and put the corresponding test tube with the same weight into the centrifugal hole.

2. Close the centrifuge cover and close the power supply. If there is a timer, set the time first and adjust the speed control knob to increase the required speed.

3. After the work is finished, the speed control knob must be adjusted to the minimum position, the timer should be set to zero, the power switch should be turned off, the power supply should be cut off, the inner cavity and rotating head should be wiped, and the centrifuge cover should be closed.


}