Overview:1、 Operation instructions of 80-5a digital speed measurement electric centrifuge 80-5a digital speed measuring table type electric centrifuge is a conventional laboratory centrifuge, which is widely used in biology, medicine, chemistry and other scie…

Consulting

1、 Operation instructions of 80-5a digital speed measurement electric centrifuge

  80-5a digital speed measuring table type electric centrifuge is a conventional laboratory centrifuge, which is widely used in biology, medicine, chemistry and other scientific research, education and production departments. The highest speed of the low-speed desktop centrifuge is 4000R / min. it is used for radioimmunoassay identification and separation of cells and large particles. The stainless steel liner is safer and the noise is lower.


Technical parameters: Note: [digital speed measurement is based on the number of rotor speed display, not constant speed]


2/SPECIFICATION:

Type   No.: 80-5a
Maximum speed: 0-5000rpm
Capacity: 15mlx24
Centrifugal force: 2335xg
Timing range: 0-60 minutes
Working power supply: 220V50Hz

 

2、 Safety notice for 80-5a desktop centrifuge: please read all instructions before using 80-5a desktop centrifuge.

1. Before operation, the hollow pipe should be evenly put into the machine, and the machine should be started to run at high speed for 1-2 minutes, and the machine can work only after no abnormality is found.

2. Do not touch the rotating head in operation.

3. It is forbidden to turn the head in the state of unbalanced loading.

4. If the wire or plug is damaged or the electrical equipment fails, it should be repaired by professionals. The use of electrical equipment not recommended by the manufacturer will cause certain quality problems.

5. Do not use in direct sunlight.

6. Do not put the machine near the high temperature heater.

7. The rated parameters of the power socket provided by the user shall be greater than that of the machine, and good grounding measures shall be taken.

8. Never move the machine while it is running.

9. Strong impact is strictly prohibited.

10. When replacing the fuse, the socket should be pulled out from the power supply.

11. When running, the centrifuge cover must be tightly covered to prevent objects from entering and damaging the machine.

12. Keep children away from the machine in use.

13. It is strictly prohibited to use metal scrubbing material for scrubbing, and soft cloth should be dipped in alkali for scrubbing.



3、 Instructions for 80-5a desktop electric centrifuge

1. The worktable of 80-5a bench type electric centrifuge should be flat and solid, and the workshop should be clean, dry and well ventilated. Before starting up, the inner cavity and the rotating head should be wiped clean, and the corresponding tubes weighed in advance should be put into the centrifugal hole.

2. Close the centrifuge cover and close the power supply. If there is a timer, set the time first and adjust the speed control knob to increase the required speed.

3. After the work is finished, the speed control knob must be adjusted to the minimum position, the timer is set to zero, the power switch is turned off, the power supply is cut off, the rotor is wiped and the centrifuge cover is closed.


}