Overview:Brief introduction of 80-5 desktop centrifuge The 24 hole centrifuge is a conventional laboratory instrument, which is widely used in scientific research, education and production departments such as biology, chemistry, medicine, etc. There are variou…
ConsultingBrief introduction of 80-5 desktop centrifuge
The 24 hole centrifuge is a conventional laboratory instrument, which is widely used in scientific research, education and production departments such as biology, chemistry, medicine, etc. There are various specifications for customers to choose from: timing and non timing, low speed and high speed, micro and large capacity, speed digital display and non digital display. Electric centrifuge is a conventional laboratory instrument, which is widely used in biological, chemical, pharmaceutical and other scientific research, education and production departments. The highest speed of low-speed desktop centrifugation is 5000r / min, which is suitable for radioimmunoassay identification and separation of cells and large particles.
Technical parameters:
Working power supply: 220V50Hz
Maximum speed: 0-5000r / min, adjustable
Maximum relative centrifugal force: 2322 × G
Working capacity: 24 × 15ml
Timing range: 0-60 minutes
Dimension: 500 * 420 * 330mm
Parameters of relevant series of desktop centrifuges:
model |
Maximum speed |
adjust speed |
centrifugal force |
Working capacity |
timing |
800 |
4000r/min |
Stepless speed regulation |
1685×g |
6×20ml |
|
800-1 |
4000r/min |
Stepless speed regulation |
1685×g |
6×20ml |
0-60分 |
80-1 |
4000r/min |
Stepless speed regulation |
1995×g |
12×20ml |
0-60分 |
80-2 |
4000r/min |
Stepless speed regulation |
1995×g |
12×20ml |
0-60分 |
Safety notice:
Before operation, the instrument should be checked for corrosion damage, the centrifugal tube for damage, please do not contact the rotating head in operation, and it is strictly prohibited to operate under unbalanced loading of the rotating head.
instructions:
The working table of the centrifuge should be balanced and fixed. The working room should be clean, dry and well ventilated. The ambient temperature should be 5 ~ 35 ℃. Before opening the centrifuge, wipe the rotating head clean, put the test tube with the same weight, close the centrifuge cover, adjust the speed control knob to increase the required speed (high speed start is strictly prohibited).
Maintenance:
After each use, turn off the power supply, clean and wipe the inner cavity and rotating head, and cover the centrifugal cover. After long-term use, the natural wear of centrifuge is normal. After the warranty period, the company will continue to provide quality service
Welcome to the official website of Runhua Instruments. We are a professional manufacturer of laboratory instruments. Quality and reputation a…
The water bath constant temperature shaker is a biochemical instrument that combines a temperature controllable constant temperature water ba…
Series of biochemical incubators:Features of 150A biochemical incubator: the biochemical incubator has the function of cooling and heating tw…
High-precision stirring water bath produced by Runhua Instruments:1) The general water bath does not have the circulating stirring function. …
Maintenance and maintenance of electric mixer1. Correct use and attention to the maintenance of the instrument to keep it in good working con…
What work should be done in the use of digital display stainless steel electric heating plate? Digital display stainless steel electric h…