Welcome to visit Changzhou Runhua Electric Co., Ltd. Official website!
TEL

0086-519-82305398

Current location:Home > Products > Oscillator series > Thermostatic oscillator
PRODUCTS
  • Bs-4g oscillation incubator double row independent constant speed intelligent temperature control recommended by manufacturers

Bs-4g oscillation incubator double row independent constant speed intelligent temperature control recommended by manufacturers

Overview:1、 Brief introduction of the instrument Constant temperature oscillation incubator, also known as (constant temperature cultivation shaker), is a biochemical instrument with heating and cooling two-way temperature regulation system, temperature contr…

Consulting

1、 Brief introduction of the instrument

  Constant temperature oscillation incubator, also known as (constant temperature cultivation shaker), is a biochemical instrument with heating and cooling two-way temperature regulation system, temperature controllable incubator and oscillator. It is an indispensable laboratory equipment for precision cultivation and preparation in plant, biology, microorganism, genetics, viral medicine, environmental protection, food, petroleum, chemical and other scientific research, education and production departments.

 

2、 Detailed introduction

Product description of constant temperature oscillation cultivation shaker:

  This series of vertical double door constant temperature cultivation shakers have three specifications: single group, double group and four groups. Due to the limitation of laboratory space, this product can also be made into double door single group double layer type, double door double group double layer type, vertical single door single layer type, vertical single door double layer type and so on


The main advantages of the vertical double door constant temperature cultivation shaker are as follows:

①the insulation material of the box is made of polyurethane foam, which has strong anti-interference ability to the external thermal (cold) source.

② Air duct is set in the working chamber, and the temperature distribution is uniform.

③ The inner wall is made of high quality mirror stainless steel with good corrosion resistance.

④ The heating system can rise to 60 ℃ at ambient temperature.

⑤ The refrigeration system can cool down to 5 ℃ at ambient temperature.

⑥ The universal spring bottle rack is especially suitable for the cultivation of biological samples for a variety of comparative tests.

⑦ Speed digital display control, speed self setting, constant speed, safe operation.

⑧ Accurate temperature control, digital display.


3、 Characteristics of constant temperature oscillation incubator:

1. There are ventilation windows to ensure fresh air in the box.

2. Programmable control.


3. The heat insulation material of the box body is polyurethane foam plastic, which has strong heat preservation performance, and the stainless steel inside the box is non-toxic.

4. The gas flow in the working chamber, and the temperature of each part is uniform. Fast heating, fast cooling and forced air convection.

5. Transparent glass door observation studio at a glance.

6. Intelligent speed regulation, you can choose the oscillation speed you need and change it at will.

Accessories: Universal spring bottle rack, suitable for various culture preparation.


4、 Detailed parameters of constant temperature oscillation cultivation shaker:

index
model


BS-4G

Volume

460L  [pallet size: 460x410mmx2 layer] the height of the first layer is 300 mm, and the height of the second layer is 500 mm

Temperature range

5-50℃

Temp Accuracy

±0.5℃  Fluctuation: ± 0.1 ℃, resolution ± 0.1 ℃

Oscillation velocity

Starting - 280r / min

Amplitude

20 mm (swing)

Number of oscillation groups

Two groups of two layers and each group of oscillation can be controlled separately with constant speed. [304 stainless steel universal fixture]

Bottling quantity

Test tube: ¢ 16 × 200 × 2 groups, 100ml × 20 × 2 groups, 250ml × 15 × 2 groups, 500ml × 2x2 groups

heating power

900W

Compressor power

480W

Power Supply

AC 220 V 50 Hz

Tank size
Dimensions


1002×490×930(mm)

1120X660X1530(mm)

 

5、 Instructions for constant temperature oscillation incubator:

1. The instrument should be placed on the flat ground, the environment should be clean and tidy, dry and ventilated.

2. Before using the instrument, all control switches should be in non working state, and the speed regulation should be set at the minimum position.

3. In order to ensure good balance performance of the instrument during oscillation and avoid large vibration, all bottle positions should be filled during bottling, and the culture medium of each bottle should be roughly equal. If the culture medium is insufficient, the test bottle can be placed symmetrically.

4. Turn on the external power supply, turn the power switch to the "on" position, and the indicator light will be on.

5. Select the culture temperature: please refer to the instruction manual.

6. Turn on the "constant speed digital display controller", the indicator light will be on, and it will be increased to the required speed according to the experimental requirements. The service life of the instrument can be prolonged if it is used at medium speed within the speed range.

7. Before each shutdown, all control switches should be in non working state and cut off the power supply

Friendly reminder: the internal parameters of the digital display meter of the oscillation incubator have been set up before delivery. Generally, there is no need to change the internal parameters without special requirements, so as to avoid work errors. Please operate according to the operation manual of the instrument when using. Thank you!


6、 Maintenance of constant temperature oscillation incubator:

1. Correct use and attention to the maintenance of the instrument, make it in a good working state, can extend the service life of the instrument.

2. After the refrigeration system stops working, clean the working chamber and glass observation window with a soft cloth.

3. During the continuous operation of the instrument, regular inspection should be carried out every three months; check whether there are water drops and dirt falling on the motor and exposed refrigeration components; clean the dust and dirt on the compressor and condenser; check the fuse, control element and fastening screw.

4. The natural wear of the oscillating incubator is normal after long-term use. After the full temperature oscillation incubator is free of warranty, our company will continue to provide quality service and lifelong maintenance.


The above constant temperature oscillation incubator model can not meet your requirements, we can produce customized according to the requirements.

Purchasing hotline: 0519-82305398 / 82306938 / 82301086 contact person: Mr. Yu


}
Video

    No video highlights...
Photo
No photo collection...
Customer
Flash Demo

Project
No related case...
Related articles
Related products
Consulting

Copyright 2020 Changzhou Runhua Electric Co., Ltd. Copyright Design by:EastNet [Manage]
Top