Overview:Product introduction Time table centrifuge is a conventional laboratory centrifuge, which is widely used in biology, chemistry, medicine and other scientific research, education and production departments. It is suitable for radioimmunoassay monitorin…
ConsultingProduct introduction
Time table centrifuge is a conventional laboratory centrifuge, which is widely used in biology, chemistry, medicine and other scientific research, education and production departments. It is suitable for radioimmunoassay monitoring and separation of cells and large particles. There are two kinds of timed and irregular centrifuges.
2、 Main technical parameters
Working power supply: 220V50Hz
Maximum speed: 4000R / min [stepless speed regulation]
Centrifugal force: 2325 × G
Working capacity: 12 × 20ml
Mechanical timing: 0-60 minutes
It is strictly prohibited to run without load without rotating head; check whether there is corrosion damage on the rotating head before operation; do not contact the rotating head in operation; do not operate under unbalanced loading condition.
4、 Instructions for use
The working table of the centrifuge should be flat and solid, the workshop should be clean, dry and well ventilated, and the ambient temperature should be 5-32 ° C. start the centrifuge and wipe the rotating head clean. Load the weighing test tube, close the centrifuge cover, set the centrifugal time according to your own requirements, adjust the speed control knob to increase the required speed, The speed control knob must be set to the minimum position, the power switch should be turned off, the power supply should be cut off, the inner cavity and the rotating head should be wiped, and the centrifuge cover should be closed.
5、 Maintenance
Do not place any objects on the centrifuge cover. After each use, be sure to clean and wipe the inner cavity and rotating head, and cover the centrifugal cover to prevent dust and dirt from entering. If the centrifuge is not used for a long time, the centrifuge cover should be opened for a period of time to dry the inner chamber. After 3000 hours of use, the carbon brush of the motor should be replaced in time to avoid wearing the commutator, Natural wear and tear is a normal phenomenon. In case of failure or difficulty after one year of use, our company will continue to provide high-quality service to assist in handling.
Changzhou Runhua Electric Appliance Co., Ltd
Address: No.26, Jinsheng East Road, Jintan City, Jiangsu Province
Tel: 0519-82305398
Fax: 0519-82306938
Website: www. runhuayiqi.com
Email: 394514722@qq.com
Welcome to the official website of Runhua Instruments. We are a professional manufacturer of laboratory instruments. Quality and reputation a…
The water bath constant temperature shaker is a biochemical instrument that combines a temperature controllable constant temperature water ba…
Series of biochemical incubators:Features of 150A biochemical incubator: the biochemical incubator has the function of cooling and heating tw…
High-precision stirring water bath produced by Runhua Instruments:1) The general water bath does not have the circulating stirring function. …
Maintenance and maintenance of electric mixer1. Correct use and attention to the maintenance of the instrument to keep it in good working con…
What work should be done in the use of digital display stainless steel electric heating plate? Digital display stainless steel electric h…