Overview:Brief introduction of td4a-ws desktop centrifuge Td4a-ws table type brushless variable frequency centrifuge is a conventional laboratory centrifuge. It is small in size and light in weight. It adopts high-quality brushless motor and digital display LE…
ConsultingBrief introduction of td4a-ws desktop centrifuge
Td4a-ws table type brushless variable frequency centrifuge is a conventional laboratory centrifuge. It is small in size and light in weight. It adopts high-quality brushless motor and digital display LED touch screen design. It can choose its own speed at will, with zero error. It is widely used in biology, medicine, chemistry and other scientific research, education and production departments. The highest speed of low-speed low-speed centrifuge is 4000R / min. it is used for radioimmunoassay identification and separation of cells and large particles. It has a stainless steel liner, which is safer and less noisy.
1、 Main technical parameters
Working power supply: 220 V, 50 Hz
Maximum speed: 4000R / min (digital display can set the speed at will)
Speed accuracy: zero error
Centrifugal force: 2200xg
Rotor capacity: 15mlx24 (angle rotor)
Rotor: 20mlx12 / 20mlx6 / 15mlx6 / 15mlx8 / 20mlx8, etc
Timing range: 1-99min
Net weight: 19kg
Overall dimension: 410 * 360 * 290mm
Control mode: microcomputer control LED display
Electric machine: brushless DC motor
Noise: ≤ 65dB (a)
2、 Safety instructions for td4a-ws bench type brushless centrifuge:
1. Before operation, the hollow pipe should be evenly put into the machine, and the machine should be started to run at high speed for 1-2 minutes, and the machine can work only after no abnormality is found.
2. Do not touch the rotating head in operation.
3. It is forbidden to turn the head in the state of unbalanced loading.
4. If the wire or plug is damaged or the electrical equipment fails, it should be repaired by professionals. The use of electrical equipment not recommended by the manufacturer will cause certain quality problems.
5. Do not use in direct sunlight.
6. Do not put the machine near the high temperature heater.
7. The rated parameters of the power socket provided by the user shall be greater than that of the machine, and good grounding measures shall be taken.
8. Never move the machine while it is running.
9. Strong impact is strictly prohibited.
10. When replacing the fuse, the socket should be pulled out from the power supply.
11. When running, the centrifuge cover must be tightly covered to prevent objects from entering and damaging the machine.
12. Keep children away from the machine in use.
13. It is strictly prohibited to use metal scrubbing material for scrubbing, and soft cloth should be dipped in alkali for scrubbing.
3、 Td4a-ws desktop electric centrifuge instructions
1. The table of td4a-ws electric centrifuge should be flat and solid, and the workshop should be clean, dry and well ventilated. Before starting up, wipe the inner cavity and the rotating head, and put the corresponding test tube with the same weight into the centrifugal hole.
2. Close the centrifuge cover and close the power supply. If there is a timer, set the time first and adjust the speed control knob to increase the required speed.
3. After the work is finished, the speed control knob must be adjusted to the minimum position, the timer should be set to zero, the power switch should be turned off, the power supply should be cut off, the inner cavity and rotating head should be wiped, and the centrifuge cover should be closed.
Changzhou Runhua Electric Appliance Co., Ltd
Address: Jintan Road, Changsheng, Jiangsu Province
Tel: 0519-892305398 80301086
Fax: 0519-82306938
website: www.runhuayiqi.com
Email: 394514722@qq.com
Welcome to the official website of Runhua Instruments. We are a professional manufacturer of laboratory instruments. Quality and reputation a…
The water bath constant temperature shaker is a biochemical instrument that combines a temperature controllable constant temperature water ba…
Series of biochemical incubators:Features of 150A biochemical incubator: the biochemical incubator has the function of cooling and heating tw…
High-precision stirring water bath produced by Runhua Instruments:1) The general water bath does not have the circulating stirring function. …
Maintenance and maintenance of electric mixer1. Correct use and attention to the maintenance of the instrument to keep it in good working con…
What work should be done in the use of digital display stainless steel electric heating plate? Digital display stainless steel electric h…